Type 05414 - Check Valve
Cryogenic-Check Valves, PN50 (DN100/150=PN40) Stainless steel body and cap with spring, opening pressure ca. 0.1 bar "cleaned and degreased for oxygen service" Part No. 05414.X.000* * Butt weld connection for stainless steel pipes acc. to ISO 1127 or ASTM A312 Part No. 05414.X.0004 Socket weld connection for stainless steel pipes acc. to ISO 1127 or ASTM A312 Available options - on request only: - Welded stainless steel stubs acc. to ISO 1127 or ASTM A312 - length FF + 200mm Applications: Approved for air gases, vapours and cryogenic liquefied gases incl. LNG. Working temperature: -196°C / -321°F (77K) up to +120°C / +248°F (393K) |
|
|||||||||||||||||||||||||||||||||||||||||
|
|
Type 05414 - Standard | Technical data | |||||||||||||
Nominal size | DN | 10 | 15 | 15 | 20 | 25 | 32 | 40 | 40 | 50 | 65 | 80 | 100 | 150 |
Dimension code | .X. | 1012 | 1517 | 1521 | 2026 | 2533 | 3238 | 4042 | 4048 | 5060 | 657x | 8088 | 0114 | 0168 |
Face-to-face dimension | FF | 70 | 85 | 85 | 100 | 115 | 115 | 130 | 130 | 155 | 205 | 245 | 280 | 400 |
Height | H | 71 | 71 | 71 | 72 | 75 | 87 | 95 | 95 | 95 | 125 | 150 | 185 | 215 |
Outside pipe-Ø ISO 1127 | RA | 12.0 | 17.2 | 21.3 | 26.9 | 33.7 | 38.0 | 42.4 | 48.3 | 60.3 | 76.1 | 88.9 | 114.3 | 168.3 |
Wall thickness pipe ISO 1127 | a | 1.0 | 1.6 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.6 | 3.2 | 6.0 | 7.1 |
Outside pipe-Ø ASTM A312 | RA | 13.72 | 17.15 | 21.34 | 26.67 | 33.40 | - | 42.16 | 48.26 | 60.33 | 73.03 | 88.90 | 114.3 | 168.3 |
Wall thickness pipe ASTM A312 | a | dimensions acc. to S10 or S40 | ||||||||||||
Socket depth | b | 6 | 10 | 10 | 13 | 13 | - | 13 | 13 | 16 | 16 | 16 | 20 | 20 |
Weight | ca. kg | 0.7 | 0.95 | 1.0 | 1.3 | 1.6 | 2.4 | 3.9 | 3.9 | 5.7 | 9.6 | 14.6 | 20.0 | 51.0 |
Kvs-Value | m³/h | 1.6 | 3.8 | 4.3 | 6.7 | 11.5 | 14.0 | 20.6 | 22.6 | 37.1 | 71.1 | 104.0 | 170.0 | 350.0 |
Cv-Value | gal/min | 1.9 | 4.4 | 5.0 | 7.8 | 13.4 | 16.2 | 23.9 | 26.3 | 43.2 | 82.7 | 120.9 | 195.2 | 401.8 |
Dimensions in mm. Compliance of tightness requirements acc. to EN 1626 for DN150 up to 20 bar differential pressure. In the range of >20-40 bar, 350-700ml (1 bar, 20°C [68°F]) are reached. |